2 Rejections

#Rejected AtQC ReviewerComments
222-JUN-2026Hugh CrawfordGood afternoon gents, please see below for items requiring attention: 1. Re-inspection-1 26th Feb 26 had 1 open deficiency (Def 2) this should be carried over onto this report as a new deficiency 2. The deficiency status for this deficiency should be recorded to show how the deficiency is now; i.e. Closed/Repaired or Open 3. Summary of findings – Summary says No LHS issues were found; if the deficiency is carried over from the previous report then this statement can be deleted If you have any questions, please give me a call
120-JUN-2026Hugh CrawfordGood afternoon gents, Please see below for items requiring attention: 1. Building location - please provide more information; where is room 4 within the hangar 2. Summary of findings – Summary says No LHS issues were found; the report has 2 deficiencies – this statement can be deleted 3. Def 1, 3, and 4 were closed on re-inspection-1 13-Jan-26; unless these issues are still present, they should be removed from this report 4. Def 2 – location is incorrect – Def does not relate to the RCD - change RCD within the CDP. to Within the CDP. If you have any questions, please give me a call